Ulbotech Protocol GPS Tracker: Setup & Wiring Guide

Ulbotech T-Series Protocol (Port 5072) Integration Guide

Ulbotech trackers are high-performance telematics units specializing in OBDII/CAN-bus data and analog sensor monitoring. All models below utilize the 5072 communication port.

 

T303

 

1. Device Comparison Table

ModelInterfaceCore FeaturesApplications
T370 / T371OBDII / Hardwire4G LTE, CAN-bus, Fuel Monitoring, FOTAHeavy Fleet, Logistics
T303 / T301HardwireAnalog (AD) Input, Immobilizer, Garmin FMICold Chain, Specialized Assets
T360 / T361OBDII PlugEasy Install, Internal Antennas, Driver BehaviorLeasing, Insurance (UBI)
T366OBDII / WIFIDual-mode GPRS/WIFI, 2-Week Data StorageRemote Areas, High-Security Fleet

2. Technical Wiring Diagrams

A. T303 Hardwire Pinout

[ T303 CONNECTOR DEFINITION ]
– PIN 1 (RED) : Power Supply (+) 9V – 100V
– PIN 2 (BLACK) : Ground (-)
– PIN 3 (ORANGE) : Ignition (ACC) Detection
– PIN 4 (YELLOW) : Relay Output (Engine Cut-off)
– PIN 5 (GREEN) : AD1 Input (Analog Fuel/Temp Sensor)
– PIN 6 (WHITE) : Digital Input / SOS Button
 

B. T370/T360 OBDII Pinout

[ OBDII J1962 STANDARD PINS ]
– PIN 4 & 5 : Ground (Chassis & Signal)
– PIN 6 (CAN H) : ISO 15765-4 High Speed
– PIN 14 (CAN L) : ISO 15765-4 Low Speed
– PIN 16 : Permanent Power (+) 12V/24V
 

3. SMS Configuration Commands

Default Password: 6666 (Replace with your actual password if changed).

1. Set IP & Port: SERVER,0,your_ip_address,5072,0#
2. Set APN: APN,6666,apn_name,apn_user,apn_pass#
3. Set Timer: TIMER,30,300# (30s moving, 300s standing)
4. Check Status: STATUS#
 

4. Fuel Sensor Calibration (Specific Steps)

Calibration is critical for converting raw analog voltage (0-5V) into liters or percentage. Follow these steps for Analog (AD) or Ultrasonic sensors.

Pre-requisite: ACC (Ignition) must be ON during calibration commands.
 

A. SMS Calibration Procedure

Send these commands sequentially as you fill or empty the tank. The device will reply with the measured value (e.g., (100, XX) where XX is the raw sensor value).

1. Fill to 100%: A000000,017,100 (Device returns raw value for Full)
2. Fill to 75%: A000000,017,75 (Device returns raw value for 75%)
3. Fill to 50%: A000000,017,50 (Device returns raw value for 50%)
4. Fill to 0%: A000000,017,0 (Device returns raw value for Empty)
 

B. Manual Table Entry (Example Data)

Record the values from the SMS replies and enter them into your Tracking Platform’s calibration section:

Calibration PointRaw Value (from Device)Actual Liters (Tank Capacity 100L)
Empty Tank1020 L
Quarter Tank34525 L
Half Tank61050 L
Full Tank980100 L
Pro Tip: For complex tank shapes (e.g., L-shaped or horizontal cylinders), use 10 or more calibration points for higher accuracy in your reports.
 

5. Conclusion

By correctly wiring the AD input (Green wire) and performing the SMS calibration sequence, Ulbotech trackers provide professional-grade fuel monitoring on Port 5072.

GPS tracking solutions
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.